Join IMDS at TCT 2026 | Booth #3218

Dual Lumen Rx Microcatheter

Simplify Complex
Bifurcations
in 6F.

Engineered for
Predictable Side Branch Access

Proximal Angulated Side Exit Port
Smallest Crossing Profile1
Radiopaque Tip

Remove stylet
enhances OTW pushability.

1. IMDS Data on File

Angled side port directs the guidewire toward the side branch for easier, more controlled access.

Radiopaque tip and exit ports enable 180° visualization for precise side branch wiring.

Reliable Bifurcation
Access & Trapping in 6F

NHancer Rx’s low 2.3F crossing profile preserves critical guide space – enabling reliable trapping and consistent dual-wire performance in 6F workflows.

1. IMDS Data on File

Smallest Crossing Profile1

Dual Lumen Microcatheters are Associated with
Higher Technical & Procedural Success1

PROGRESS CTO Registry | n = 1,353 patients

PROGRESS CTO Registry | n= 1,353 patients

Technical Success

87.1%
74.3%
p < 0.001

Procedural Success

83.8%
73.5%
p = 0.001
Dual LumenSingle Lumen (Dual-Wire Attempt)

Higher Success, Despite Greater Lesion Complexity

J-CTO Score
2.59vs 2.06p < 0.001
Moderate / Severe Calcification
53.3%vs 30.8%p < 0.001
Proximal Cap Ambiguity
39.5%vs 28.7%p = 0.001

1. PROGRESS-CTO Registry (Brilakis ES, et al. CCI, 2025). *Based on complex CTO cases after failed antegrade wiring attempts.

Engineered Together
for Complex CTO Scenarios

Designed to work seamlessly with NHancer Rx, TrapIT enables true 6F OTW capability – preserving dual-wire position for controlled, consistent bifurcation access.

Product Specifications

2.3F

Oval distal shaft – smallest crossing profile in class

135 cm

Usable length, exit markers at 95 and 105 cm

2 x 0.014″

Guide wire compatibility OTW and Rx lumens

Stylet

Removable, for adjustable push and trackability

Hydrophilic coated • Radiopaque atraumatic tip • Reinforced shaft • 0.48 mm shaft inner diameter • PFAS free • See IFU for complete specifications

Technical Data
Proximal Profile2.6F (0.86 mm)
Distal ProfileOval low profile design 2.3F x 3.3F
Lesion entry profile1.5F
Guide wire compatibility OTW Lumen0.014″
Guide wire compatibility Rx Lumen0.014″
Distal shaft coatingHydrophilic >15 cm
Exit markers95 cm and 105 cm
Tip designSoft tapered tip
Order Information
Model numberNRX1413518
Guide catheter compatibility5F
Usable length135 cm

CE Registration under device name NHancer Rx Dual Lumen Rapid Exchange Catheter. PFAS Free.

Downloads and Related Links

Please see the Instructions for Use for a complete listing of the indications, contraindications, warnings and precautions. Caution: Federal Law (U.S.) restricts this device to sale by or on the order of a physician. NHancer Rx™ is a trademark of IMDS.