Join IMDS at TCT 2026 | Booth #3218

Dual Lumen OTW Microcatheter

The Frontline
Approach for
Antegrade CTO.

One Solution. Dual Access.
Forward Progress.

ReCross dual-lumen OTW microcatheter delivers the control, support and redirection needed to stay on strategy – without device exchange.

96%
Technical Success1
in Antegrade (ADA) CTO

1. Ayoub, M., Mozid, A., Philip, L., Millan, X., Khatri, J., Ungureanu, C., Bennett, J., Ghafari, C., & Avran, A. (2025). Use of ReCross to Increase Success Rate With Antegrade CTO PCI — A Multicenter Observational Study. Catheterization And Cardiovascular Interventions, 106(1), 654–662.

True Distal Tip &
Exit Port Visibility

Two Separate OTW Lumens & Three Exit Ports
360° Guide Wire Redirection
Trappable in 6F

Remove stylet
improves overall pushability.

Radiopaque tip and exit ports enable 360° visualization for precise positioning and predictable direction.

ReCross Increases Procedural Efficiency &
Cost Control in Complex CTO PCI (N=118)1

Only 3 guidewires neededon average for successful CTO crossing

Standard guidewire success rate with ReCross combination (%)

  • 47.5%Gaia® (Asahi Intecc)
  • 27.1%Gladius® (Asahi Intecc)
  • 13.6%Fielder® (Asahi Intecc)
  • 7.6%Confianza® (Asahi Intecc)
  • 0.8%Sion® (Asahi Intecc)

Successful CTO strategies (antegrade crossing) with ReCross (%)

  • 47%Parallel Wiring
  • 29%Antegrade wire escalation
  • 18%Antegrade dissection re-entry
  • 6%Other / none successful
90 min
avg. procedural time
37 min
avg. angio time

1. Ayoub, M., et al. (2025). Catheterization And Cardiovascular Interventions, 106(1), 654–662.

Versatility Across
Complex CTO Scenarios

ReCross’ dual-lumen 360° design enables support to perform multiple advanced techniques from a single microcatheter.

Compatible with TrapIT, enabling efficient OTW trapping in 6F.

Product Specifications

2 + 3

Two OTW lumens, three radiopaque exit ports

8/12 mm

Opposed side ports, measured from the tip

140 cm

Usable length, OTW platform

2.3F / 3.3F

Distal / proximal shaft profile – trappable in 6F

0.014″ guidewire compatible • 5F guiding catheter compatible • Removable stylet • Radiopaque soft tip • Dual hubs (tip lumen + stylet lumen) • See IFU for complete specifications

Technical Data
Guide wire compatibility0.014″
Shaft designReinforced Shaft
Shaft profileOval Shaft 2.3F x 3.3F
Exit Markers95 cm and 105 cm
CoatingHydrophilic
Usable Length150 cm
Lesion entry profile1.5F
Order Information
Model numberRC1414025
Guide catheter compatibility5F
Usable length150 cm

CE Registration under device name ReCross OTW Dual Lumen Guide Wire Support Catheter. PFAS Free.

Downloads and Related Links

Please see the Instructions for Use for a complete listing of the indications, contraindications, warnings and precautions. Caution: Federal Law (U.S.) restricts this device to sale by or on the order of a physician. ReCross™ is a trademark of IMDS.